一、Product introduction:LT-604is the catlyst at the copper non-electroplating redox reaction. It’s main elements are Pd, organic acid, stannous chloride ion, Sn2 + by instability, anxious to release two electronic, and 1-13 + solution due to their own Sn2 + oxidative stress, receive two electronics, reduced palladium metal deposition in the hole wall.
二、Operate condition:
LT-604 3-5%
temperature 30-35℃
time 5-8 minutes
三、 Compound method :
LT-604 4%
LT-603 200 grams / liter
CP hydrochloric acid5%
四、 Groove maintan:
1、Shoud not mix with Air mixing ;
2、Obviously cylinder liquid color changes, solution stratification and copper content of more than 2 g / liter when to be replaced;
3、Strict control of the ingredients prepreg cylinder stability, not to add water level, the level dropped with LT - 603 Solution supplement;
4、Each handle 100m2 of additional board space 800ml LT-604 dope, or the results of additional testing;
5、 Acidity should be maintained at 0.7-1.0N between the proportion should be controlled in 16-19Be ° color control than in 60-100%;
6、 Increased acidity of 0.1N need of additional CP-9ml hydrochloride / L, adding bacterial / L LT - 603 can improve the proportion of 1Be °.
五、 Wastewater treatment : Caustic adjusted to pH 7 after removing sediments, and disposal.
六、 Anlyse method
1.Colorimetric Analysis :
a、Preparation of a small cup of the new LT - 603 prepreg working fluid;
b、Admission sufficient current activator LT-604 to 100 ml flask, increase above prepreg to work on Level, shaking after more than 100% for color standard solution;
c、Admission than five 10ml color tubes, respectively affixed with a 60%, 70%, 80%, 90%, 100% of the label from flask learned 6ml, 7ml, could provide adequate, 9ml, 10ml color than the standard solution were placed at colorimetric tube, from the new LT - 603 prepreg dan working fluid, 3ml, 2 ml, 1 ml, bet-placed colorimetric tube, after shaking sealed for 60%, 70%, 80%, 90%, 100% standard color solution;
d、Admission 10mlLT-604 Activator working fluid in color than 10ml tube above, and the color standard solution than comparing it in scope; Color standards than on the storage time should not exceed one month |