一、Product description:LT - 603 is used on the surface adjustments before it‘s activated, is also used to ensure the concentration stability of LT-604.
二、Operation condition:
LT - 603 200 grams / liter
CP-5% hydrochloric acid
The temperature room temperature
Time 1-2 minutes
Filtering Regular use 5-10 µ mp. P cotton filter core
Not boost
三、 Confect method:
LT - 603 200 grams / liter
CP-5% hydrochloric acid
DI water allowance
四、 Tank liquor maintan:
1、 To maintain the proportion of 16-19Be °, each adding bacterial / L LT - 603 can improve 1Be °;
2、 Dealing with 100m2 per board area required addition of LT - 603 3 kg;
3、 Maintaining pH 0.5-0.7N, each adding 9ml / L can improve HCL acidity 0.1N;
4、 copper content> 1.0 g / liter (Bath dark green) per liter or working fluid handling 20m2 plate replacement fluid;
五、Analysis method:
1. Acidity analysis:
a、 Inject 1ml to 250ml bottle Cone, add 50ml deionized water, coupled with 2-3 drops phenolphthalein indicator;
b、 Titrate with 0.1N sodium hydroxide to end at the pink, the number of titration is V;
c、 Calculation: acidity (equivalent / L) = 0.1 × V
d、 Control range: acidity 0.5-0.7N
The proportion 16-19Be ° |