一、Product description :LT-601Cleaner has a good basic performance of alkalescence, its main role is wetting, infiltration, adsorption, and the adjustment process to complete insulation layer PCB surface of the micro-state of adjustment, so as to provide reliable micro-surface conditions for the follow-up process hole.
二、Distribution groove:
Chemical Name |
quantity |
DI water |
90% V/V |
Cleaner |
10% V/V |
三、Operation condition:
|
range |
the best condition |
temperature |
50-60℃ |
55℃ |
concentration |
10-15% |
12% |
四、Tank liquor maintain :
1.Using the same concentration of liquid to supplement the daily consumption level;
2. Add LT – 601 according to the analysis of the solution concentration, maintaining the solution equivalent concentration and pH;
3. Add 0.8liter LT – 601 after produce 100m2 plates;
4. Need to change the slot when the solution copper ion concentration is 1 g / liter or a liter fluid production is about 20m2.
五、 Analysis Method:
1.Analysis of LT-601:
a、 Using a transferring tubeto get 1 ml to 250 ml conical liquid bottle, add 100ml water and 4 drops of methyl orange indicator;
b、 Using droplets 0.1N HCl standards set to end at the red, a few milliliters of titration V;
c、Calculate :LT-601(V/V)=V×0.1×0.25
2. copper ion:
a、 Using a transferring tube to get 1 ml to 250 ml conical liquid bottle, add 100ml water;
b、Add 40ml acid, 2 - 3 drops PAN indicator;
c、 Using 0.1N EDTA standard droplets to violet to the end, the number of titration ml V;
d、Calculation: copper ion (g / L) = 0.64 × V |